Menü

FTP Error Codes

ERROR CODEDESCRIPTION
0000INTERCHANGE_OK;-every validation passedthrough successfully
0016AWAITING_ DELIVERY_TO_REMOTE_SERVICE;-interchange has a status of 0000 (no errors) and it is waiting to be delivered to a trading partner on another VAN
303INVALID_PASSWORD;-position security information in element ISA04 is not empty and the content is not correct
304UNKNOWN_RECIPIENT;-the recipient given in element ISA08 is unknown
306INCOMPLETE_FILE;-missing any start or end segment of any envelope loop ISA must be followed by IEA, GS must be followed by GE and ST must be followed by SE
307INTERCHANGE_CONTROL_NUMBER_MISMATCH;-the interchange controlnumber from ISA13 and from the corresponding IEA02 are not identical
308FUNCTIONAL_GROUP_CONTROL_NUMBER_MISMATCH;-the group control number from GS06 and the from the corresponding GE02 are not identical
309NVALID_NUMBER_OF_FUNCTIONAL_GROUPS;-the number of included functional groups from element IEA01 does not match the number of GS/GE pairs included within the interchange
310TRANSACTION_CONTROL_NUMBER_MISMATCH;-the transaction set control number from element ST02 does not match that one from corresponding SE02 element
311MESSAGE_TRAILER_COUNT_MISMATCH;-the number of included transaction sets from element GE01 does not match the number of ST/SE pairs included within this functional group
312INVALID_NUMBER_OF_TRANSACTION_SEGMENTS;-the number of included segments in one ST/SE loop does not match the number in SE01
315UNEXPECTED_INTERCHANGE_HEADER_FAILURE;-the ISA segment does not have at least 106 characters.
317UNKNOWN_SENDER;-the sender given in element ISA06 is unknown
325SENDER_ID_DOES_NOT_MATCH_MAILBOX_ID;-the sender given in element ISA06 does not match the mailbox name
393DUPLICATE_EAP_KEYWORD;-transaction set control number from SE02 is not unique within the functional group
421SERVICE_NOT_AVAILABLE;-service not available, closing connection, Internal server error: retry session
dupeDUPLICATE_INTERCHANGE;-the interchange is totally identical to an already successfully sent Interchange
8999MORE_THAN_ONE_GS_GE_LOOP_FOUND;-furthermore, we do not support multiple GS/GE loops
9994NO_INTERCHANGE_ENVELOPE;-the uploaded document contains no interchange envelope
9996NO_GS_GE_LOOP_FOUND;-the interchange loop contains no functional group (GS/GE loop)
9997INVALID_NUMBER_OF_ELEMENTS_IN_ISA_SEGMENT;-the ISA segment has less than 13 elements. elements 14, 15 and 16 are not relevant.
9998NO_ISA_SEGMENT; -no ISA segment found
9999INVALID_DOCUMENT; -any other mistake